Pull cylinders with reset spring

Pull cylinders with reset spring

This single-acting pull cylinder is suitable for smaller plants which are 

tact-independent. The built-in release spring only serves for bringing 

the piston into edge-on position. The edge-on time depends on several 

conditions. So, an exact edge-on time can not be calculated. 


If feed and edge-on are to act tact-dependent and/or force-stressed 

in a set interval, we recommend to use double-acting cylinders

(see data sheet 200-3).


HYDROKOMP offers the pull cylinder with threaded connection and 

O-ring flange connection in various designs.


When mounting the pull cylinder, for example through the cross holes,

it is important to have the cylinder to the front form-closed supported

starting with an operating pressure of 250 bar and up, in so far as the

mounting is made transverse to the direction of force.  


The user also has to prevent foreign particles and liquids from ingress

into the spring area of the pull cylinder by a cover or preventive cylinder

arrangement.  If desired, an air supply line can be additionally connected.